11 Program Functions

11.8.5.2 Flat roof

Flat roof

Image 11.198 Generate Wind Loads - Flat Roof dialog box

RFEM considers a roof to be flat if the roof inclination α < 5°.

First, define the standard and, where applicable, the National Annex in the Velocity Pressure dialog section. This setting controls, which text boxes can be accessed.

Specify the parameters as described in Chapter 11.8.5.1. The Eaves Type dialog section is linked to the interactive dialog graphics that illustrate the individual settings.

As described in EN 1991-1-4, Table 7.2, for example, several load cases must be taken into account for a flat roof. In the Load Cases to Generate dialog section, specify the load case numbers for the load generation. The compression loads are created in load case LC w+, the suction loads in LC w-. The relevant load cases can be created with the button.

After confirming the generator dialog box with [OK], RFEM displays the results of the load generation for all load cases in an overview (see Figure 11.201). The dialog tabs represent an important control option because the external pressure coefficient cpe,10 and the external pressure we are displayed by zones for each load case.