4x
001606
2024-09-30

Size Factor for Compression for Sawn Lumber and CLT

Calculation of the size factor for compression for sawn lumber and for CLT (KZc) according to CSA O86:1, Section 6.5.5.2.4
KZc = 6.3  (d  L)-0.13
KZc = 1.24

;