60x
001030
2023-12-29

Adjusted Minor Axis Bending Design Value, Fby'

Adjusted Minor Axis Bending Design Value, Fby'

Fby' = Fb2 = Fb · CD · CM · CL · Ct · Cfu · CF · Ci · Cr
Fby' = Fb2 = 1,100 psi · 1.6 · 1.0 · 1.0 · 1.0 · 1.1 · 1.0 · 1.0 · 1.0
Fby' = Fb2 = 1,936 psi

Fby'

Adjusted minor axis bending design value, psi

Fb

Reference bending design value, psi

CD

Load duration factor

CM

Wet service factor

CL

Beam stability factor

Ct

Temperature factor

Cfu

Flat use factor

CF

Size factor

Ci

Incising factor

Cr

Repetitive member factor



;