53x
000868
2024-10-07

Interaction Conditions According to EN 1993-1-8, Section 7.4.2, Equation 7.3

Interaction conditions according to EN 1993-1-8, Section 7.4.2, Equation 7.3
Ni,EdNi,Rd + Mop,i,EdMop,i,Rd  1.0
197.56257.36 + -0.085.92 = 0.78 < 1.0  S1
-186.89257.36 + -0.015.92 = 0.72 < 1.0  S2
Ni,Ed Design value of the acting axial force for the structural component i
Ni,Rd Design value of the axial force resistance of the connection for the structural component i
Mop,i,Ed Design value of the acting moment out of plane of the structural system for the structural component i
Mop,i,Rd Design value of the moment resistance of the connection for bending out of plane of the structural system for the structural component i
S1 Strut 1
S2 Strut 2

;