Ni,Ed | Design value of acting axial force for structural component i |
Ni,Rd | Design value of axial force resistance of connection for structural component i |
Mop,i,Ed | Design value of acting moment out of plane of structural system for structural component i |
Mop,i,Rd | Design value of moment resistance of connection for bending out of plane of structural system for structural component i |
Interaction conditions according to EN 1993-1-8 Chapter 7.4.2 Equation 7.3
Interaction conditions according to EN 1993-1-8 Chapter 7.4.2 Equation 7.3