The ultimate responsibility for quality assurance lies with the user of the simulation software. It is their responsibility to prevent unsuitable software choices or improper application, as specified in VDI 6201. The software manufacturer must verify their products and the integrated models and validate them based on reference examples. The user is obliged to perform a basic validation of the software concerning the specific application area before independent use.
If the results of a CFD calculation are used for dimensioning purposes, different levels of validation are required depending on the consequence class (CC) of the structure or component, according to the WTG guidelines.
CC | Structures (Examples) | Recommendation |
4 | Complex geometries or dynamics | Validation through tests in specialized wind tunnels, variant studies |
3 | Slender bridges, high-rise buildings | Validation through a wind tunnel test |
2 | Structures of medium importance | Plausibility check by an independent expert, e.g., an experienced structural engineer |
1 | Minor structures where failure is unlikely | Comparison |