Design Check Calculation

Mcr = 1.127 · π2 · 21000 kNcm2 · 10140 cm41 · 650 cm2 · 112 · 2883000 cm610140 cm4 + 1.0 · 650 cm2 · 8076.92 kNcm2 · 292.5 cm4π2 · 21000 kNcm2 · 10140 cm4+  0.454 · 18 cm2  - 0.454 · 18 cm 
Mcr = 115310 kNcm = 1153.10 kNm
λ¯LT = Wpl,y · fyMcr = 2683 cm3 · 23.5 kNcm2115310 kNcm = 0.739
ϕLT = 0.5 · 1  0.34 · 0.739 - 0.4  0.75 · 0.7392 = 0.762
χLT = 10.762  0.7622 - 0.75 · 0.7392 = 0.85 < 1

;