11 Program Functions

11.7.2.2 Surfaces

Surfaces

Vaulted head according to DIN 28011 or DIN 28013
Image 11.174 Generate Vaulted Head dialog box, Structure tab

For creating a vaulted head, RFEM provides the standard variants Torispherical head and Semi ellipsoidal head. Once the reference point for placing the head is set in the General Data tab, you can define the material and the generator parameters for surface thickness, outer diameter, and border height in the Structure dialog tab. In the Loads dialog tab, it is possible to additionally specify overpressure as a surface load for the generation.

Barrel roof
Image 11.175 Generate Barrel Roof dialog box, Loads tab

You can define the parameters of the barrel roof in the Basis and Structure dialog tabs. In the Loads tab, enter the required data for creating the snow load cases.

Domed roof
Image 11.176 Generate Domed Roof dialog box, Structure tab

You can specify the parameters of the domed roof in the Basis and Structure dialog tabs. In the Loads tab, enter the required data for the creation of snow load cases.

Surfaces from cells
Image 11.177 Create Surfaces from Cells dialog box

Cells consist of at least three corner nodes. They are enclosed by lines or members on all sides and lie in one plane. To fill cells with surfaces, define the Material and Thickness of the surface first. Then, graphically select the cells with by clicking the cell crosses in the work window.