The upper part of the window lists the governing designs sorted by load cases and load combinations. The lower part includes detailed information on the internal forces and design parameters of the load case selected above.
Description
This column provides the descriptions of the load cases and load combinations for which the designs were performed.
Nodes No.
This column displays the number of the node with the maximum design ratio for the designed action.
Design Ratio
Columns C and D show the design conditions according to [1], [2], or [5]. The length of the colored bar represents the respective design ratio graphically.
Design According to Formula
This column lists the equations of the standard that were used for the designs.
Literature