The Slant screws fastener is currently the only available timber-to-timber joint category.
The following joint types are available:
Main member only |
Fastening of a member to an existing component (or any number of members) at any angle |
|
Front to side |
Connection of a diagonal member to a continuous beam (Main member and Continuous member) |
|
Front to front |
Free definition of a node with a connected member |
This section is only accessible for the Front to front joint type. With an inclined secondary member, the connection can be symmetrical or asymmetrical (cf. Figure 9.6).
Symmetrical connection at an angle of 45° |
|
Main member cut perpendicularly to member axis |
|
Secondary member cut perpendicularly to member axis |
The design-relevant coefficients are specified according to the standard and the National Annex (see Figure 2.19).
If you want to apply user-defined factors for the designs, you have to create a new National Annex first by clicking the button. Afterwards, the coefficients can be customized in the National Annex Settings dialog box (cf. Figure 9.10).
According to [2] 8.7.2(3), the minimum embedment depth of the threaded part on the side of the screw head should be six times the screw diameter d. If necessary, the factor for determining the minimum penetration tpen,min can be adjusted in this section.