143x
005619
2024-08-08

CFD Solver

The current RWIND 3 version recommends using the external CFD code OpenFOAM®. In particular, a special, natively compiled OpenFOAM® version from CFD Support called "OpenFOAM® for Windows," version 17.10 is utilized. The source code is based on the OpenFOAM® version distributed via openfoam.org and is included in the installation of the RWIND 3 program.

The numerical solver is called "RWINDSimulationSolver" and it is related to the SIMPLE family of solvers. It is a steady-state solver for incompressible, turbulent flow, using the SIMPLE (Semi-Implicit Method for Pressure Linked Equations) algorithm.

Since OpenFOAM® is distributed under the GNU GPLv3 license, the RWINDSimulationSolver is distributed under the same license and its source code can be found in the RWIND 3 installation directory, subdirectory "OF\src". For more information about OpenFOAM®, visit the website CFD Support, or contact CFD Support directly using [email protected]. Trademark disclaimer: This offering is not approved or endorsed by OpenCFD Limited, a producer and distributor of the OpenFOAM software via www.openfoam.com and an owner of the OPENFOAM® and OpenCFD® trademarks.

The result of the calculation is a three-dimensional field of velocity and pressure covering the entire computational domain; that is, the wind tunnel. Pressure values on the model boundary (exterior surfaces of buildings) are then used to calculate the forces representing the wind load.

The methods used theoretically allow for a very precise simulation of such flow, provided that the computational mesh is sufficiently fine (for example, tens of millions of mesh cells). However, such calculations are very time-consuming and thus expensive. Furthermore, the preparation of such calculations, for example, topology cleanup and generation of an optimal mesh, often requires considerable effort and experience. RWIND 3 has thus been designed to be very easy to use and to get approximate results on relatively coarse meshes in a very short time, typically within several minutes. If greater accuracy is desired, the user can obtain more precise results by increasing the mesh density – the capacity and performance of RWIND 3 is limited only by the available memory and the number of processors/cores used for the parallel calculation.

Parent Chapter