538x
000464
2024-01-10

Governing Results

In these result tables, you can display the governing design results and their corresponding internal forces. Various sorting options are available (by member or member set, and by member end or member set end).

The tables initially show all available design checks at the corresponding location. For this, there is the output of internal forces that lead to the maximum ratio in the respective design. If you only want to display the internal forces related to the governing design at a location, you can select "Max" for the ratio in the result filter.

The internal forces of the governing design checks at member ends or member set end can give you an indication of which load combination could be governing at this location for the connection design, for example.

The Result Table Manager provides additional filter options, for example, by limit state (an ultimate limit state or a serviceability limit state) and by design check type (cross-section design or stability design).

Parent Chapter