827x
001244
2020-11-06
The boiler supporting structure with a combustion chamber is used as the main stiffening element of the coal‑fired plant in Neyveli, Tamil Nadu, India.

The boiler supporting structure measures 100 ft x 100 ft x 406.8 ft and, together with the boiler roof arranged above, it has to withstand loads of about 50.706 t.

The engineering office of Voss & Kamb, a customer of Dlubal Software, was in charge of the structural analysis and the connections.

Structural Analysis
Voss & Kamb und Partner GmbH, Kaiserslautern, Germany
www.voka-kl.com

3D model of boiler supporting structure and deformation in RSTAB (© Voss & Kamb und Partner GmbH)

(0)
0 out of 5 stars
5 star 0
4 star 0
3 star 0
2 star 0
1 star 0

Boiler Steel Supporting Structure 

No Download Possible Customer Project / View Only
Number of Nodes 1921
Number of Members 2094
Number of Load Cases 87
Number of Result Combinations 69
Total Weight 6062.012 tons
Dimensions (Metric) 70.000 x 52.650 x 125.725 m
Dimensions (Imperial) 229.66 x 172.74 x 412.48 feet
Program Version 8.05.00
Report this 3D Model