4x
001524
2024-08-26

Spring Constants – Hinged Column Head, Restrained Column Base, Elastic Nodal Support, Neglecting Shear Stiffness

These formulas are used to calculate the spring constants of the stiffness using a fictitious column for a hinged supported column, without considering shear stiffness.
CuX=3·EIzH3
CuY=3·EIyH3
CuZ=EAh
CφY=0