2058x
002672
2019-03-22

Display of Internal Forces on Result Members

No internal forces are displayed for result members in my model. How can I change this?


Answer:

Make sure that the "Results on Result Members" option is activated for result members in the Display navigator. If it is deactivated, no internal forces are displayed.


Author

Ms. Effler is responsible for the development of products for dynamic analysis and provides technical support for our customers.

References
  1. Dlubal Software. (2018). Manual RFEM. Tiefenbach.