Determination of the largest column load in 3D models

How do I obtain the maximum column load in my RFEM 3D model?


Answer:

The following points should be considered in order to use the determined internal forces for the design:

  • The model should represent the real structure as precisely as possible. Therefore, it is necessary to correctly define the materials, surface thicknesses, cross-section dimensions, hinge definitions, support conditions, and so on.
  • Loads must be defined and applied in compliance with the standard. RFEM can import the combinations automatically.
  • In the case of internal forces from result combinations, it is necessary to pay attention to the evaluation of the correct max/min values. The maximum compression force in a column corresponds to the minimum axial force (min N).

Author

Mr. Flori is the customer support team leader and provides technical support for customers of Dlubal Software.



;