In the Modal Analysis add-on, you have the option of automatically increasing the desired eigenvalues until a defined effective modal mass factor is reached. All translational directions activated as masses for the modal analysis are taken into account.
Thus, it is possible to easily calculate the required 90% of the effective modal mass for the response spectrum method.