20x
001473
2024-04-11

θmax

θ should not exceed the lesser of θmax, given by the equation, as the structure is potentially unsafe and should be redesigned.

θmax  = 0.10.5βCd0.25
Cd Deflection amplification factor in Table 12.2-1
β Ratio of shear demand to design shear capacity for the story between levels x and x-1 (taken conservatively as 1.0, but not less than 1.25/Ω0)

;