An axially loaded steel beam with a square cross-section is pinned at one end and spring supported at the other. Two cases with different spring stiffness are considered. Neglecting its self-weight, determine the critical load scaling factors by the linear stability analysis.
Model Used in
Verification Example 000005 | 4
Number of Nodes | 2 |
Number of Members | 1 |
Number of Load Cases | 1 |
Dimensions (Metric) | 1.500 x 0.500 x 0.500 m |
Dimensions (Imperial) | 4.92 x 1.64 x 1.64 feet |
Program Version | 8.04.00 |
You can download this structural model to use it for training purposes or for your projects. However, we do not assume any guarantee or liability for the accuracy or completeness of the model.