2980x
003176
2019-06-17

Предупреждение 30014 при расчете расчетного сочетания

При расчете расчетного сочетания, я получаю «Предупреждение № 30014 - Неправильное добавление загружений в расчетное сочетание! The result combination contains load cases or load combinations with results containing second-order effects, which points towards nonlinear relationships and therefore cannot be added together…" What does this warning mean?


Ответ:

Это предупреждение появляется в случае следующих заданий расчетных сочетаний, когда загружения/сочетания нагрузок рассчитываются в соответствии с нелинейным расчетом, таким как метод второго порядка или расчет по большим деформациям.

Case 1: RC = LC1/CO1 + LC2/CO2

For Case 1, load cases/load combinations cannot be superimposed together in a result combination when each case/combination is ran according to a nonlinear analysis such as a second-order (P-Delta, p-delta) or large deformation analysis. Deformations in both load cases are based on different structural systems and will result in incorrect results, as P-Delta effects cannot be simply added together.

The solution for this case is to either run the load cases/load combinations according to a geometrically linear analysis, where the results can be superimposed together in a result combination, or the combined load cases must only be considered under the Load Combinations tab and evaluated individually rather than in a result combination.

Keep in mind, this same warning will appear when creating a result combination in a model where geometric nonlinearities are also defined. An example includes a slab foundation where a nonlinear surface support is defined to fail in the case of uplift. Geometric nonlinearities can accurately be considered in load combinations, as opposed to result combinations which may yield incorrect summary results.

Case 2: RC = Factor* LC1/CO1 or Factor* LC2/CO2

For Case 2, if a load case/load combination is calculated according to a nonlinear analysis, it is not possible to additionally apply a factor to the result combination. The factor would not only be applied to the defined loads on the structure, but also to the nonlinear effects such as P-Delta, which is incorrect.

The solution for this case is to either run the load cases/load combinations according to a geometrically linear analysis, where the factor can be applied to the result combination, or the factor can be considered under the Load Combinations tab, where it will be applied directly to load cases according to a geometrically linear analysis only, without considering the second-order effects.


Автор