CSA S16 Classe 4 Sezione

La mia sezione è classificata come Classe 4 e non progettabile in RF-/STEEL CSA. However, my manual calculation shows a different class. Why the difference?


Risposta:

I rapporti massimi b/t e h/w si basano sulla Tabella 1 o sulla Tabella 2 a seconda delle forze interne nelle aste. For members subject to pure axial compression, Table 1 is used. For members subject to flexure or flexure+axial (beam-column), Table 2 is used.

In RFEM, the preset setting is to neglect the bending moment if the ratio is less than 1%. Therefore, the program shows “Class 4” since the check is based on Table 1.

To change this setting, go to Details and set the limit values to zero (as shown in Image 1). By doing so, the program runs the check per Table 2 and no longer ignore the small moments.

Note: In the example model, where moments are zero at the support locations, the result is still shown as “Class 4 (non-designable)”.